This product is a single-component or two-component moisture-cured polymer waterproofing coating engineered for high-stress structural surfaces. Upon curing, it forms a seamless, highly elastic, rubber-like membrane with exceptional peel adhesion to concrete, metal, and existing membrane substrates. It accommodates dynamic structural movement and resists persistent hydrostatic pressure in demanding commercial and civil engineering environments. Certified under ISO 9001 quality management standards and tested in accordance with international ASTM protocols.
Technical Specifications
|
Property |
Test Standard |
Typical Value |
|
Base Material |
Chemistry |
Modified Polyurethane / SPUR |
|
Solid Content |
ASTM D2697 |
>= 92% |
|
Tensile Strength |
ASTM D412 |
>= 3.5 MPa |
|
Elongation at Break |
ASTM D412 |
>= 600% |
|
Peel Adhesion (Concrete) |
ASTM C794 |
>= 1.8 N/mm (Concrete failure) |
|
Hydrostatic Pressure Resistance |
ASTM D5385 |
>= 0.5 MPa (No leakage, 30 min) |
|
Tack-Free Time |
ASTM C679 |
4 - 6 hours (23 deg C, 50% RH) |
|
Application Temperature |
Substrate |
+5 deg C to +35 deg C |
Key Features
Monolithic Seam-Free Layer: Eliminates lap-joint failure points common in prefabricated sheet membranes.
High Substrate Grip: Forms covalent and mechanical bonds with concrete substrates, preventing lateral water migration if punctured.
Dynamic Crack Bridging: Accommodates up to 2.0 mm of substrate crack movement without tearing.
Moisture-Tolerant Curing: Cross-links via reaction with ambient atmospheric moisture; applicable on damp (surface dry) concrete substrates.
Chemical Resistance: Resists mild acids, alkalis, and de-icing salts commonly found in industrial and civil settings.
Application Areas
Subterranean Structures: Retaining walls, foundation slabs, and basement waterproofing.
Horizontal Decks: Podium decks, plaza decks, parking structures, and balconies before tile or screed installation.
Roofing Systems: Exposed flat roofs, inverted roofs, and green roof podiums.
Civil Engineering: Tunnel portals, utility trenches, and sewage treatment plant secondary containment.
Suitable Substrates
Concrete: Cured concrete (>= 28 days, moisture content < 4%, compressive strength >= 25 MPa).
Cementitious Screeds: Polymer-modified repair mortars and self-leveling compounds.
Metal: Primed structural steel and galvanized decking.
Existing Membranes: Sound, fully adhered bituminous or polyurethane membranes (after compatibility testing and scarification).
Application Method
Surface Preparation: Shot-blasting, grinding, or acid etching to remove laitance, curing compounds, and contaminants. Achieve a concrete surface profile (CSP) of 3 to 4. Ensure surface is dust-free and structurally sound.
Priming: Apply an epoxy or polyurethane penetration primer at 0.15 - 0.20 kg/m2 to seal pores and eliminate outgassing.
Detailing: Apply reinforcement fabric embedded in a coating stripe coat at internal corners, pipe penetrations, and construction joints.
Base Application: Apply the coating in two cross-directional coats using a notched trowel, heavy-duty roller, or airless spray equipment. Maintain a wet film thickness (WFT) of 0.8 - 1.0 mm per coat to achieve the target dry film thickness (DFT) of 1.5 - 2.0 mm.
Curing Protection: Protect from rain, foot traffic, and mechanical damage for at least 24 hours post-application.
Packaging & Storage
Packaging Formats: 20 kg / 25 kg metal pails; 200 kg steel drums for large-scale application.
Shelf Life: 12 months from manufacture date in unopened, original containers.
Storage Conditions: Store in a dry, shaded warehouse between +5 deg C and +25 deg C. Keep away from direct sunlight, ignition sources, and moisture exposure.
OEM & ODM / Customization
Formulation Adjustments: Viscosity tuning for roller vs. spray application; adjustable curing speeds for cold-weather (0 deg C) or tropical (40 deg C) job sites.
Color Matching: Standard colors include grey and white; custom RAL shades available for exposed deck applications (MOQ applies).
Private Labeling: Custom lithographed pails, laser-coded batch numbers, multilingual technical data sheets (TDS), and safety data sheets (SDS) matching regional regulatory standards (e.g., OSHA, REACH, CE compliance documentation).
Manufacturing & Quality Control
Production Capacity: Two automated reaction kettles with a combined annual output of 15,000 tons, operated under ISO 9001 quality management systems.
Process Control: Closed-loop vacuum dispersion mixing to eliminate entrapped air and ensure homogenous pigment/filler distribution. Viscosity and solid content tested inline every 500 kg batch.
Batch Testing: Retain samples kept for 24 months from every manufactured batch. Full physical property testing (tensile, elongation, peel strength) conducted per certified laboratory protocols prior to release.
Product Selection Guide
|
Project Requirement |
Recommended Grade |
Viscosity |
Key Reason |
|
Vertical Walls & Details |
TH-Grade (Thixotropic) |
High (Paste) |
Non-sag performance on vertical surfaces up to 2.0 mm vertical application. |
|
Large Horizontal Decks |
SP-Grade (Self-Leveling) |
Medium |
Rapid roller/squeegee application with self-smoothing finish. |
|
Spray Application |
AS-Grade (Low Viscosity) |
Low |
Optimized for airless plural-component spray rigs on large square-meter projects. |
FAQ
Q: Can this coating be applied directly to green concrete?
A: No. Concrete must cure for a minimum of 28 days with a moisture content below 4%. High moisture vapor transmission (MVT) will cause blistering and delamination of the membrane. Use a moisture-tolerant epoxy moisture barrier primer if early application is required.
Q: What is the minimum required dry film thickness (DFT) for hydrostatic pressure resistance?
A: For positive-side hydrostatic pressure up to 0.5 MPa, a minimum DFT of 1.5 mm is required, typically applied in two separate coats to prevent pinhole formation.
Q: Is a protective screed or topping required on horizontal applications?
A: For non-trafficable roofs, a UV-resistant topcoat is sufficient. For pedestrian or vehicular decks, a cementitious screed, protection board, or asphalt overlay must be installed over the membrane to prevent mechanical puncture from foot traffic or aggregate loading.
Hot Tags: high-adhesion polymer waterproof coating, China high-adhesion polymer waterproof coating manufacturers, suppliers, factory, concrete bonding waterproof coating, industrial waterproof coating system, Low-VOC Waterproof Coating, polyurethane waterproof coating, structural waterproof coating, Two component Polyurethane Waterproof Coating